Varen er på fjernlager, leveringstiden er 14-21 hverdage. Mere info
Leveringsmuligheder - Vælges ved checkout
GLS - Pakkeshop
Fri fragt
DAO - Hjemmelevering om natten og i de tidlige morgentimer
Perfekt til arbejdsdage - Levering inden kl. 06:00 - Klar når du vågner
9,00
GLS - Levering til hoveddøren
59,00
Afhentning i vores Pick-up point i Ringsted
Fri fragt
Vis alle leveringsmuligheder (4)
DKK
22.313,00
ex. moms 17.850,40
Total inkl. fragt
22.313,00
Funktionen kræver at man er logget ind. Opret en bruger og brug vores smarte liste system til at holde styr på fremtidige indkøb, faste indkøb eller ønskelister. Opret bruger Login
SINAMICS G120D Control Unit CU240D-2 PN-F FO PROFINET and Safety Integrated via fiber-optic cable in push-pull version 6 DI/3 F-DI, 2 DO/1 F-DO, 2 AI HTL encoder interface Degree of protection IP65 Ambient temperature 0 to +45 °C without Power Module SINAMICS CU240D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. The CU240D‑2 Control Units supersede the CU240D Control Units, whereby both versions can be operated with PM250D Power Modules. The Control Units are available in different versions, for example, in CU240D-2 DP, CU240D-2 DP-F, CU240D-2 PN, CU240D-2 PN-F, CU240D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU240D-2 PN-F FO (Fiber Optic). The safety function Safe Torque Off (STO) is already integrated into the standard versions of the CU240D‑2 series (CU240D‑2 DP and CU240D‑2 PN). It can be activated either via PROFIsafe or via the safety input. With the fail-safe variants of the CU240D‑2 series (CU240D‑2 DP‑F xx and CU240D‑2 PN‑F xx), the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS - the integrated drive family for every field of application.
Højde
208 mm
Vægt
1,5 kg
Pakkebredde
175 mm
Pakkedybde
135 mm
Pakkehøjde
242 mm
Pakkevægt
1,53 kg
Hurtig start guide
Ja
Compliance-certifikater
CE, RoHS, REACH
Produktet er kendt under følgende varenumre i vores system
EAN:
4042948697023
SKU:
6SL35440FB211FC0
Hvorfor oplever jeg at den umiddelbart samme vare findes på forskellige varenumre?
Producenterne udgiver ofte den samme vare med forskellige varenumre, typisk handler det udelukkende om forskellige versioner af emballagen. Eksempelvis kan emballagen være målrettet forskellige lande.
Vi forsøger bedst muligt at samle varerne, men det kan opleves at den samme vare figurerer på forskellige varenumre i vores system.