FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Fjernlager (1-2 hverdage)
Varen er på fjernlager, leveringstiden er 1-2 hverdage. Mere info
Leveringsmuligheder  - Vælges ved checkout
Instabox - Pakkeboks
Fri fragt
GLS - Pakkeshop
Fri fragt
DAO - Hjemmelevering om natten og i de tidlige morgentimer
Perfekt til arbejdsdage - Levering inden kl. 06:00 - Klar når du vågner
9,00
GLS - Levering til hoveddøren
59,00
Afhentning i vores Pick-up point i Ringsted
Fri fragt
DKK 1.265,00
ex. moms 1.012,00
Total inkl. fragt 1.265,00
RM17 UB3 and RM35 UB3 Three-Phase Voltage Control Relay
Schneider Electric RM17/35 UB measurement and control relays for 3 phase supplies, monitor correct sequences of phases L1, L2 and L3. It also monitors total loss of one or more phases, asymmetry, and over and undervoltage with independent adjustments. In the event of voltage fault, the relay opens at the end of the time delay set by the user, if the device is switched on with a measured fault, the relay remains open.
Checks its own power supply
Clear hinged front cover
Potentiometer selects voltages between phases
LED display of output status
DIN Rail mounting
Standards
NF EN 60255-6 and IEC 60255-6
Approvals
UL, CSA, GL, C-Tick, GOST
Schneider Electric Harmony Control Series Monitoring Relay, DPDT Contact Configuration, Voltage Monitoring Application - RM35UB330
This monitoring relay is crucial for voltage management in electrical systems, protecting equipment by detecting overvoltage and undervoltage conditions across three phases. It operates within a voltage range of 194 to 528V AC, making it essential for optimal performance in various industrial applications. Its features contribute to reliable and safe monitoring in modern electrical setups.
Features & Benefits
- Adjustable time delay from 0.3 to 30 seconds enhances responsiveness.
- DPDT relay configuration allows for flexible wiring options.
- Provides comprehensive overvoltage and undervoltage protection.
- Designed for straightforward installation on a standard DIN rail.
- Durable construction with a high electrical lifecycle rating.
Applications
- Monitoring voltage levels in 3-phase supply systems.
- Suitable for electrical monitoring devices in industrial environments.
- Effective in situations where overvoltage protection is necessary.
- Essential for automation systems that need consistent voltage management.
What is the maximum voltage that can be sensed by this device?
It can accurately sense voltages up to 528V AC.
How do I adjust the time delay for fault response?
The time delay can be easily adjusted on the front panel.
Can it be mounted in any position?
Yes, it can be installed in any position without derating.
What types of connections does it support?
It supports screw terminals for various wire sizes and types.
What should I do if I experience measurement inaccuracies?
Measurement accuracy is within +/-10%