Black Box ClimateCab - Rack air-conditioning køle system
FBAC4895-B52C-4E03-B099-A6A8F8B8017B Created with sketchtool. 706D6907-81E1-46A2-B8F9-7B702A1EF2C7 Created with sketchtool. 6A870209-E7F5-44F5-A66F-09E20C85A0DC Created with sketchtool. 0BB04D6C-A9AB-4913-BF4F-5A23954E68E1 Created with sketchtool. 501E26C7-66C1-4DAA-B740-6CFAF55A1B39 Created with sketchtool. C105F7D3-D5EE-43C9-9EE8-05CC42B296D4 Created with sketchtool. D94689D8-7CBB-41C8-AC06-F79D81FF82D5 Created with sketchtool. DA4C7ED9-2512-4D52-94F0-92800F2A6E04 Created with sketchtool. 42E133FD-828F-4CF4-A0BF-560014487A57 Created with sketchtool. F52D9745-4BFD-4506-BEEF-630FD09EF2D9 Created with sketchtool.
Ikke på lager
Varen er ikke på lager. Mere info

Udsolgt

Varen er ikke på lager.

Brug funktionen ”Giv mig besked..." herunder for opdateringer.

Leveringsmuligheder  - Vælges ved checkout
Fragtmand til kantsten.
199,00
Afhentning i vores Pick-up point i Ringsted
Fri fragt
Fragtprisen er baseret på levering til postnr.: 4140 - Borup skift postnr.
Angiv postnr til levering: Gem
DKK 20.700,00
ex. moms 16.560,00
Total inkl. fragt 20.899,00
Giv mig besked når varen er på lager igen
Control heat and humidity in your ClimateCab Cabinet. These models are perfect for harsh environments and remote locations without cooling infrastructure. Air-Conditioning units keep equipment cool even with temperatures up to 55degreeC. A closed-loop cooling system recirculates air in the cabinet and keeps outside air out while an internal evaporator eliminates condensation. Cabinet sides are pre-machined to match the air conditioner. The sides are fixed to the cabinet using screws and a rubber gasket. Sturdy handles and hooks at the base of the side panel reduce the physical effort required to fit the air conditioner. Sealing gaskets supplied with the air conditioner are inserted around the edges of both apertures. No specialist tooling or skills are required to install the Climatecab Server Cabinet. Controls The air conditioner can be run with no special controls set however the settings may be modified to accommodate most applications by removing a panel and adjusting three DIP switches. A 5-wire connection block is supplied for wiring to a door open switch or alarm panel. Door Open A pair of connections may be used to stop the air conditioner from operating when the door is open. This prevents condensed water from collecting on the cold plates of the air conditioner. Alarm A pair of volt free contacts can be used to signal an alarm condition. Typically this is an over-temperature and a pair of DIP switches enable the setting of the threshold for temperatures over 45 50 55 or 60degreeC. The connector block to attach the alarm and door open wires is included in the pack. Temperature The internal temperature of the cabinet may be set to 25 30 35 or 40degreeC by changing the position of the three DIP switches.